Low-voltage battery
TR Pro.
LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter.
- INVERTER
- Compatible external inverter required
- ENCLOSURE
- IP66
- NOMINAL ENERGY
- 10.24 / 16.076 kWh
- BATTERY VOLTAGE
- 51.2 V nominal DC
Specifications
| Model / configuration | Energy (kWh) | Rated DC (kW) |
|---|---|---|
| TR6000WX-Pro | 10.24 | 10 |
| TR8500WX-Pro | 16.076 | 10 |
| TR8500WX-ProU | 16.076 | 10 |
Self-heating is optional. Power ratings are battery-side DC; actual AC output depends on the selected inverter.
| Model | Dimensions (mm) | Approx. kg |
|---|---|---|
| TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 |
| TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 |
| TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 |
Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C
PRODUCT DETAIL / ORIGINAL LITERATURE
Every side. Every connection.
The panel illustrates one wheeled representative housing rather than proving every Pro SKU has the same lower body or port placement. Roller is a wheel. Main Circuit Breaker and Battery Switch are separate source labels. Full embedded switch-photo content beyond the printed crop is not promoted to new interface claims.
Know your interfaces.
Power connections
- Positive battery terminal
- Positive DC battery terminal identified on the connection side.
- Negative battery terminal
- Negative DC battery terminal identified on the connection side.
Communication
- RS485
- RS485 interface named in the source; pinout and compatible device list are not provided.
- Wi-Fi antenna
- Wi-Fi antenna identified by the original arrow.
- CAN
- CAN communication interface named in the source; protocol version and pinout are not specified.
- RS232
- RS232 communication interface named in the source; pinout is not specified.
- COM1
- Port named COM1; this page does not explicitly define its role or wiring.
- COM0
- Port named COM0; this page does not explicitly define its role or wiring.
Controls & indicators
- Breathing light
- Front status-light strip identified as a breathing light. Colour meanings and operating logic are not specified.
- Main circuit breaker
- Main circuit breaker identified by the original arrow. Trip ratings and wiring are not provided here.
- Battery switch
- Battery switch separately named in the connection-side callout; do not merge this label with Main Circuit Breaker without a model-specific manual.
Structure & mounting
- Wall-mounted bracket
- Mechanical wall-mounting bracket; not an electrical interface.
- Rollers
- Wheels shown on the representative housing. The label is mechanical and is not a connector or bottom communication port.
- Folding handle
- Mechanical folding handle; not an electrical connector.
Source: Residential ESS brochure · PDF page 4 · printed pages 7-8